customizable length sliding contact line (45) Online Manufacturer
Flame Retardancy: V0 Grade
Environmental Indicators: Ambient Temperature: -25℃-40℃, With The Average Temperature Variation Not Exceeding 35℃ Within Any 24-hour Period; Relative Humidity Can Reach 100% At An Ambient Temperature Of 25℃.
Effective Service Length: 3016mm
Shell Protection Rating: IP33, Customizable IP54
Withstand Current: 4.5KA
Equivalent Copper Cable Cross-section: 12mm²
Rated Peak Withstand Current: 6.5KA
Configured Quantity Of Current Collector (pcs): 1
Insulation Resistance Between Poles And Between Poles: >5MΩ
Electrothermal Stability: 20 Times The Rated 1st Imes Rated For 1s
Transmission Guide Rail Parameters: Guide Rail Parameters Compliant With GB/T 7251.6 - 2015 Low - Voltage Switchgear And Controlgear - Part 2:<< Particular Requirements For Busbar Trunking Systems (busway)>>
Vibration And Shock Resistance: 10-2000HZ
Effective Service Length: 1508mm
Shell Protection Rating: IP33, Customizable To IP54
Transmission Guide Rail Parameters: Guide Rail Parameters Compliant With GB/T 7251.6 - 2015 Low - Voltage Switchgear And Controlgear - Part 2:<< Particular Requirements For Busbar Trunking Systems (busway)>>
Corrosion Stability: Acid-resistant, Alkali-resistant, Salt Spray Corrosion-resistant
Transmission Guide Rail Parameters: Guide Rail Parameters Compliant With GB/T 7251.6 - 2015 Low - Voltage Switchgear And Controlgear - Part 2:<< Particular Requirements For Busbar Trunking Systems (busway)>>
Electrothermal Stability: Imes Rated For 1s
Environmental Indicators: Ambient Temperature: -25℃-40℃, With The Average Temperature Variation Not Exceeding 35℃ Within Any 24-hour Period; Relative Humidity Can Reach 100% At An Ambient Temperature Of 25℃.
Rated Peak Withstand Current: 6.75KA
Environmental Indicators: Ambient Temperature: -25℃-40℃, With The Average Temperature Variation Not Exceeding 35℃ Within Any 24-hour Period; Relative Humidity Can Reach 100% At An Ambient Temperature Of 25℃.
Transmission Guide Rail Parameters: Guide Rail Parameters Compliant With GB/T 7251.6 - 2015 Low - Voltage Switchgear And Controlgear - Part 2:<< Particular Requirements For Busbar Trunking Systems (busway)>>
Effective Service Length: 3016mm
RAted Operate Volatge: AC 380-690V
Net Weight Per Single Rail: 6.7kg
Transmission Guide Rail Parameters: Guide Rail Parameters Compliant With GB/T 7251.6 - 2015 Low - Voltage Switchgear And Controlgear - Part 2:<< Particular Requirements For Busbar Trunking Systems (busway)>>
Insulation Resistance Between Poles And Between Poles: >5MΩ
Flame Retardancy: Level V0
Matching Current Collector Model: GHJD-B-80A
Transmission Guide Rail Parameters: Guide Rail Parameters Compliant With GB/T 7251.6 - 2015 Low - Voltage Switchgear And Controlgear - Part 2:<< Particular Requirements For Busbar Trunking Systems (busway)>>
Flame Retardancy: Level V0
Insulation Resistance Between Poles And Between Poles: >5MΩ
Send your inquiry directly to us